The HI98191 is a rugged, portable pH/ORP/ISE meter with the performance and features of a benchtop meter. This professional,
waterproof meter complies with IP67 standards and measures pH, ORP, ISE, and temperature. The HI98191 is supplied with all necessary accessories to perform a pH/temperature measurement packaged into a durable carrying case.
Details
For the measurement of pH the HI98191 comes with a HI72911B titanium body pH electrode with a built in temperature sensor for automatic temperature compensated readings. The titanium body is chemically resistant to aggressive chemicals and is virtually unbreakable.
Calibration can be performed up to five points with seven preprogrammed standard pH buffers and five custom ones to achieve a pH accuracy of ±0.002 with ±0.001 pH resolution.
Hanna's unique CAL Check™ feature alerts the user to potential problems during the pH calibration process. By comparing previous calibration data to the current calibration the meter will alert the user with display prompts when the probe needs to be cleaned or is broken and if the pH buffer might be contaminated. After calibration the overall probe condition is displayed as a percentage from 0 to 100% in increments of 10%. The probe condition is affected by both the offset and slope characteristics of the pH electrode and is displayed on the measurement screen on the day of calibration and in the GLP data.
The HI 98191 has 15 different ISE sensors (ISE-electrod not included) pre-programmed with the ion charge and molar weight. By selecting the appropriate ISE in the ISE Setup Menu, the appropriate ion charge and ion molar weight are applied to display ISE slope percentage. Users can then calibrate up to five points with the choice of seven standard values. This meter allows an extensive choice of measurement units (ppm, ppt, g/L, ppb, µg/L, mg/mL, M, mol/L, mmol/L, % w/v, user defined) and has an expanded measuring range of 1.00 x 10-7 to 9.99 x 1010.
Pressing the "AutoHold" virtual key seen in measurement mode, the meter will freeze a stable reading allowing for the reading to be documented or logged. An “out of calibration range” warning can be enabled that will alert the user when a reading is not within the bracket of calibrated pH values.
Access help at any time at a press of a dedicated button and view content specific information based on the screen that is currently being viewed.
The high contrast graphic LCD is easy to read outdoors in bright sunlight as well in low-lit areas with the backlight.
PRIMARY APPLICATIONS: Food & Beverage, Plating, Water and Wastewater, Chemical Manufacturing, Agriculture, and Environmental
Ordering Information HI98191 is supplied with HI72911B titanium body pH electrode, 100 mL plastic beaker (2), 1.5V AA batteries (4), HI92000 PC software, HI920015 micro USB cable, instruction manual, quick start guide, instrument quality certificate and HI720191 hard carrying case.
Specification | Detail |
---|---|
pH Range | -2.0 to 20.0 pH / -2.00 to 20.00 pH / -2.000 to 20.000 pH |
pH Resolution | 0.1 pH / 0.01 pH / 0.001 pH |
pH Accuracy (@25°C) | ±0.1 pH / ±0.01 pH / ±0.002 pH |
pH Calibration | Up to five point calibration, seven standard buffers available (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45), and five custom buffers |
mV Range | ±2000.0 mV |
mV Resolution | 0.1 mV |
mV Accuracy | ±0.2 mV |
Temperature Range | -20.0 to 120.0 °C |
Temperature Resolution | 0.1 °C |
Temperature Accuracy (@25°C) | ±0.4 °C (excluding probe error) |
ISE Range | from 1.00 E⁻⁷ to 9.99 E¹⁰ concentration |
ISE Resolution | 3 digits 0.01; 0.1; 1; 10 concentration |
ISE Accuracy | ±0.5% of reading (monovalent ions), ±1% of reading (divalent ions) |
ISE Calibration | up to five point calibration, six standard solutions available (0.1, 1, 10, 100, 1000, 10000 ppm) |
Temperature Compensation | manual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F) |
Log Feature | 300 samples (100 each pH/mV/ISE range) |
Connectivity | PC Connectivity - opto-isolated USB with optional HI 92000 software and micro USB cable |
GLP | Yes |
Power Supply | 1.5V AA batteries (4 pcs.) |
Power Consumption | approx. 200 hours of continuous use without backlight (50 hours with backlight) |
Environment | 6 to 50 °C max. RH 100% IP67 |
Dimensions | 191 x 93 x 35.2 mm |
Weight | 406 g |
Ordering Information | HI98191 is supplied with HI72911B titanium body pH electrode, HI7004M pH 4.01 buffer solution (230 mL), HI7007M pH 7.01 buffer solution (230 mL), HI700601 electrode cleaning solution sachet (2 x 20 mL), 100 mL plastic beaker (2), 1.5V AA batteries (4), HI92000 PC software, HI920015 micro USB cable, instruction manual, quick start guide, instrument quality certificate, and HI720191 hard carrying case. |
Warranty | 2 years Electrode:6 Months |
Recommended Probe | HI72911B Titanium body, pH electrode with internal temperature sensor, BNC connector and 1 m cable |