Turbidity meter ISO Visa större

Turbidity meter ISO

HI-98713

Ny

Item no. HI-98713

Mer detaljer

11 890 kr

Portable Turbidity Meter with Fast Tracker™ Technology, ISO

Two, three or four point calibration
USB and RS 232 PC connectivity
Log up to 200 records
GLP Features
User friendly, backlit LCD display with guidance codes
Battery % on startup
Continuous current time on display

The HI 98713 meets and exceeds the requirements of the ISO 7027 for water quality and provides a reliable and accurate readings on low turbidity values. An effective algorithm calculates and converts the detectors output in FNU. Depending on the needed accuracy, normal, continuous, or signal averaging can be selected.

The optical system—The Infrared Method (ISO 7027), consists of a infrared LED and two detectors (scattered and transmitted light), that assures long term stability and minimizes stray light and color interferences. HI 98713 also compensates for variations in intensity of the LED, minimizing the need for frequent calibration.

This instrument incorporates complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. The last calibration points, time and date can be checked at the touch of a button.

With it’s logging function, up to 200 measurements along with it’s tagged locations can be stored in internal memory and consulted at any time. Data can be later transferred to a PC via RS232 or USB interface and HANNA HI 92000 software (optional).

Exclusive Fast Tracker™

For advanced field applications, the HI 98713 is equipped with Fast Tracker™—Tag Identification System (T.I.S.) that makes data collecting and management simpler than ever. Fast Tracker™ allows users to record the time and location of a specific measurement or series of measurements.

Order Information:

HI 98713-02 (230V) is supplied with sample cuvettes and caps (5), HI 98713-11 calibration cuvettes, HI 93703-58 silicone oil, cuvette cleaning cloth, batteries, AC adapter, instructions and rugged carrying case.

Accuracy ±2% of reading plus 0.1 FTU
Auto Shut-off After 15 minutes of non-use
Calibration Two, three or four point calibration
Display 60 x 90 mm LCD with backlight
Environment 0 to 50°C (32 to 122°F); max 95% RH non-condensing
IR Detector Silicon Photocell
Light Source 860 nm infrared LED
Logging Memory 200 records
Method Adaptation of ISO 7027, ratio method with 90° and 180° detector.
Power Supply 4 x 1.5V AA alkaline batteries or AC adapter
Range 0.00 to 9.99 FTU 10.0 to 99.9 FTU 100 to 1000 FTU
Range Selection Automatically
Repeatibility ±1% of reading or 0.01 FTU, whichever is greater
Resolution 0.01 FTU from 0.00 to 9.99 FTU 0.1 FTU from 10.0 to 99.9 FTU 1 FTU from 100 to 1000 FTU
Serial Interface RS232 and USB 1.1
Standards < 0.1, 15, 100 and 750 FTU
Stray Light < 0.1 FTU
Typical EMC Deviation ±0.05 FTU