+46 300 40 40 18
Beställ innan kl 16.00 för leverans dagen efter. Endast vardagar

Svenska

Currency: SEK

Menu
Hanna HI-83414-02 Turbidity and Free and Total Chlorine Meter

HI-83414-02

The HI-83414 is a multiparameter instrument that measures the most important parameters in drinking water – turbidity and chlorine.

2 year manufacturers' warranty

30 298.87 kr Exl. moms
37 873.59 kr (inkl. moms)
Beskrivning Specifikation

HI-83414-02 Turbidity and Free and Total Chlorine Meter

The HI-83414 is a multiparameter instrument that measures the most important parameters in drinking water – turbidity and chlorine.

The instrument is based on a state-of-the-art optical system which provides accurate results by minimising stray light and colour interferences. Periodic calibration with the supplied standards compensates for any variations in intensity of the tungsten lamp.

The colorimeter portion of the meter uses a 525nm narrow band interference filter for maintaining the proper wavelength in the measurement of free and total chlorine. All measurements are performed with 25mm round cuvettes composed of special optical glass to ensure maximum repeatability of turbidity and chlorine measurements.

More benefits:

  • EPA Compliant
  • Backlit Graphic LCD
  • Light blocking cuvette cover
  • Four measurement modes
  • Multiple turbidity units of measure
  • Multiple reading modes
  • Calibration - 2, 3, 4 or five-point turbidity calibration, plus warning messages
  • CAL Check™
  • Out of Cal Range function
  • GLP data
  • Data logging
  • Data Transfer
  • Tutorial mode
  • Contextual help

Läs mer

Turbidity Range – non-ratio mode 0.00 to 9.99 NTU
10.0 to 40.0 NTU
0.0 to 99.9 NTU
100 to 268 Nephelos
0.0 to 9.80 EBC
Turbidity resolution – non-ratio mode 0.01; 0.1 NTU; 0.1; 1 Nephelos; 0.01 EBC
Turbidity Range – ratio mode 0.00 to 9.99 NTU
10.0 to 99.9 NTU
100 to 4000 NTU
0.0 to 99.9 NTU
100 to 26800 Nephelos
0.00 to 9.99 NTU
10.0 to 99.9
100 to 980 EBC
Turbidity resolution – ratio mode 0.01; 0.1 NTU; 0.1; 1 Nephelos; 0.01; 0.1, 1 EBC
Free and Total Chlorine Range 0.00 to 5.00 mg/L
Range Selection Automatic
Free and Total Chlorine Resolution 0.01 mg/L from 0.00 to 3.50mg/L
0.10 above 3.50 mg/L
Turbidity Accuracy ±2% of reading plus 0.02 NTU; ±5% of reading above 1000 NTU
Free and Total Chlorine Accuracy ±0.02 mg/L @ 1.00 mg/L
Repeatability ±1% of reading or 0.02 NTU, whichever is greater
Stray Light < 0.02 NTU
Light Source tungsten filament lamp
Light Detector Silicon Photocell
Turbidity Method Ratio Nephelometric Method (90° and 180°), adaptation of the USEPA Method 180.1 and Standard Method 2130 B
Free and Total Chlorine Method Adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G
Turbidity Standards < 0.1, 15, 100, 750 & 2000 NTU
Free and Total Chlorine Standards 1.00 mg/L free chlorine, 1.00 mg/L total chlorine
Turbidity Calibration Two, three, four or five point calibration
Free and Total Chlorine Calibration one-point calibration
Logging Memory 200 records
Serial Interface USB
Environment up to 50°C (32 to 122°F); max 95% RH non-condensing
Power Supply 230 Vac adapter
Auto Shut-off After 15 minutes of non-use
Dimensions 230 x 200 x 145 mm
Weight 2.5kg
Order Information HI-83414-02 is supplied with sample cuvettes and caps (5), calibration cuvettes for turbidity (HI-88703-11) and colorimeter (HI-93414-11), silicone oil (HI-98703-58), cuvette wiping cloth, scissors, power cord and instruction manual.