Conductivity Bench-Top Meter with ATC Visa större

Conductivity Bench-Top Meter with ATC

HI-2315-02

Ny

Item no. HI-2315-02

Mer detaljer

4 125 kr

Bench-Top Conductivity Meter

PRIMARY APPLICATIONS:
* Municipal drinking water, environmental studies
* Printing industry - Fountain solution maintenance
* Water Treatment - Boiler/Cooling Tower water quality
* Agriculture - Fertilizer concentration
* Food processing - salt levels in food. (i.e. making pickles)
* Education - Teach students about EC

The HI-2315 Bench-Top Conductivity Meter is a multi-range meter with built-in automatic temperature compensation for testing Conductivity. 

The HI2315 utilizes a four ring potentiometric probe with platinum sensor that offers greater versatility and accuracy over amperometric designs.

A potentiometric probe works on the principal of induction which eliminates the effects of polarization (a common problem of amperometric systems). Two outer rings apply an alternating voltage and induce a current loop in the solution while two inner rings measure the voltage drop induced by the current loop (which is dependent on the conductivity of the solution). By utilizing the 4-ring method, it is possible to measure very low to high conductivity levels (up to 200 mS/cm) without changing probes.

FEATURES/BENEFITS:
* Four ring potentiometric platinum probe
* Four measurement ranges
* ±1% F.s. accuracy
* Manual calibration
* Automatic Temperature Compensation
* Large LCD
* Built-in Solution Holders

FEATURES IN DEPTH:
Four ring probe - This allows for 1 probe to measure 4 ranges with no polarization effect. It provides an increased accuracy (1% F.S.) over amperometric style meters.

Manual calibration - This simple to use feature allows the HI2315 Bench-Top Conductivity Meter to be calibrated to any value within the measurement ranges (0.0 to 199.9 µs/cm; 0 to 1999 µs/cm; 0.00 to 19.99 ms/cm; 0.0 to 199.9 ms/cm) It is also less expensive than models with auto-calibration

Manual adjustable temperature correction coefficient (ß = Beta) - This simple to use feature allows for different temperature correction coefficients to be used based on the sample being tested. It is adjustable from 0-2.5%/°C.

Automatic Temperature Compensation - This helps provide the HI 2315 with higher accuracy since conductivity is very sensitive to temperature variations.

Large LCD - The new, larger LCD is bright and easy to read.

Built-in Solution Holders - The HI 2315 has solution holders built into the casing. This convenient feature saves space and prevents solutions from tipping over.

Recessed Connector Bay - Protects connectors from liquids.

Order Information:
 HI 2315-02 (230V) are supplied with HI 76303 Platinum 4-Ring Potentiometric Conductivity Probe, 12 VDC adapter and instruction manual.

Accuracy (@20°C/68°F) ±1% F.s. (excluding probe error)
Calibration Manual, one point
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Power Supply 12 Vdc adapter (included)
Probe HI 76303, platinum four ring conductivity probe with internal temperature sensor, Din connector and 1 m (3.3') cable (included)
Range 0.0 to 199.9 µS/cm; 0 to 1999 µS/cm; 0.00 to 19.99 mS/cm; 0.0 to 199.9 mS/cm
Resolution 0.1 µS/cm; 1 µS/cm; 0.01 mS/cm; 0.1 mS/cm
Temperature Compensation Automatic, 0 to 50°C (32 to 122°F)with ß adjustable from 0 to 2.5%/°C